pannels
 
 
MNPV4HV-Disco 3R - Basic Combiner

MidNite MNPV4HV-Disco 3R - Basic Combiner

MidNite MNPV4HV-Disco 3R - Basic Combiner
MNPV4HV Disco 3R - Basic Disconnecting Combiner has 80 amp busbars, 100 amp load break rated switch has two poles in series. Pictured with included front cover removed.

  • Nema 3R aluminum enclosure (no rust, won't turn to dust)
  • 90o C terminals
  • See thru deadfront & color coded busbar guards included
  • Meets 2011 NEC
  • Load Break Rated
  • Model number MNPV4HV Disco 3R Basic
  • Does not include: SPD600, fuses, fuse holders or strain reliefs. No positive feedback to Birdhouse.
  • Product Detail:

    Availability
    Usually ships within 48 hours


    Qty.Sale Price
    1 +$308.88


    Part Num. Quantity  
    COLO-00972

    Additional Information:



    A new section in Article 690 of the NEC codes will be introduced to increase the electrical and fire safety of photovoltaic (PV) systems on buildings-in particular, for the emergency responders working on or near the power lines that may potentially contain live PV circuits. For PV systems installed on roofs of buildings, PV source circuits will be required to de-energized within 10 seconds of when emergency shutdown is initiated or when the PV power source disconnecting means is opened. Local municipalities are already starting to require the use of the Emergency Shutdown system. (City of Anaheim Fire Dept Specs & Req) MidNite Solar has all the needed equipment to install the Emergency Shutdown systems, including the battery disconnect modules to allow for disabling anything battery based including the Inverter and AC generator. Actual html for cut and paste: A new section in Article 690 of the NEC codes will be introduced to increase the electrical and fire safety of photovoltaic (PV) systems on buildingsā€”in particular, for the emergency responders working on or near the power lines that may potentially contain live PV circuits. For PV systems installed on roofs of buildings, PV source circuits will be required to de-energized within 10 seconds of when emergency shutdown is initiated or when the PV power source disconnecting means is opened.

    Local municipalities are already starting to require the use of the Emergency Shutdown system. (City of Anaheim Fire Dept Specs & Req) MidNite Solar has all the needed equipment to install the Emergency Shutdown systems, including the battery disconnect modules to allow for disabling anything battery based including the Inverter and AC generator.

    PDFs:

       Spec Sheet
       Manual Instructions
       Brochure