MidNite Solar MNPV16HV-Disco Nema 4X Combiner

MidNite Solar MNPV16HV-Disco Nema 4X Combiner
MNPV16HV Disco 4X PV Disconnecting Combiner, 5 poles, 100 amp load break rated or 175 amps load break rated for busbars and switch. Picture shows included front cover removed. For additional information, see the PDF links below.

Features:
  • Convertible configuration (field configurable)
  • Sixteen strings combined for up to 230 Amps single pole disconnect)
  • 8 + 8 strings, separate PV+ and PV- for use with 2 inverters (2 pole 115A disconnect)
  • 8 strings plus, 8 strings minus for use with non-isolated inverters (2 pole 115A 600VDC disconnect)
  • Disconnect switch has built in shunt trip with positive feedback
  • See thru deadfront & color coded busbar guards included
  • Birdhouse compatible
  • Optional PV connected power supply
  • Load Break Rated
  • Optional AC connected power supply for redundancy
  • MNSPD600 lightning arrestor included
  • Nema 4X aluminum enclosure (no rust, won't turn to dust) conduit/strain relief holes punched
  • Accepts 1/2" strain reliefs included or 3/4"
  • Hole plugs supplied
  • 90 DEG C connections
  • Fuseholders included
  • 15A/600A fuses included
  • Meets NEC 2011
  • Size: 21.6"L x 19.9"W x 5.8"D
  • Weight: 27 Lbs
  • MN Part Number: MNPV16HV-Disco Nema 4X Combiner
  • Product Detail:

    Availability
    Usually ships within 48 hours


    Qty.Sale Price
    1 +$1007.28


    Part Num. Quantity  
    COLO-00978

    Additional Information:



    A new section in Article 690 of the NEC codes will be introduced to increase the electrical and fire safety of photovoltaic (PV) systems on buildings-in particular, for the emergency responders working on or near the power lines that may potentially contain live PV circuits. For PV systems installed on roofs of buildings, PV source circuits will be required to de-energized within 10 seconds of when emergency shutdown is initiated or when the PV power source disconnecting means is opened. Local municipalities are already starting to require the use of the Emergency Shutdown system. (City of Anaheim Fire Dept Specs & Req) MidNite Solar has all the needed equipment to install the Emergency Shutdown systems, including the battery disconnect modules to allow for disabling anything battery based including the Inverter and AC generator. Actual html for cut and paste: A new section in Article 690 of the NEC codes will be introduced to increase the electrical and fire safety of photovoltaic (PV) systems on buildingsā€”in particular, for the emergency responders working on or near the power lines that may potentially contain live PV circuits. For PV systems installed on roofs of buildings, PV source circuits will be required to de-energized within 10 seconds of when emergency shutdown is initiated or when the PV power source disconnecting means is opened.

    Local municipalities are already starting to require the use of the Emergency Shutdown system. (City of Anaheim Fire Dept Specs & Req) MidNite Solar has all the needed equipment to install the Emergency Shutdown systems, including the battery disconnect modules to allow for disabling anything battery based including the Inverter and AC generator.