MidNite MNPV8HV-Disco Nema 3R Combiner

MidNite MNPV8HV-Disco Nema 3R Combiner
MNPV8HV Disco 3R PV Disconnecting Combiner, 5 poles, 80 or 160 amp busbars depending on how they are configured. Switch is a 100 amp load break rated or 175 amps load break rated depending on configuration. Picture shows included front cover removed. For additional information, see the PDF links below.

  • Convertible configuration (field configurable)
  • Eight strings combined for up to 160 Amps single 230 Amp/600V single pole disconnect)
  • 4 + 4 positive strings, separate PV+ and PV- for use with 2 inverters (2 pole 115 Amp disconnect)
  • Four strings positive, four strings minus for use with non-isolated inverters (2 pole 115 Amp disconnect)
  • Disconnect has built in shunt trip with positive feedback
  • Birdhouse compatible
  • Load Break Rated
  • Optional PV connected power supply
  • Optional AC connected power supply for redundancy
  • Nema 3R aluminum enclosure (no rust, won't turn to dust)
  • 90 DEG C connections
  • MNSPD600 Lightning Arrestor included
  • 1/2" strain reliefs and hole plugs included
  • See thru deadfront & color coded busbar guards included
  • Fuseholders included
  • 15A/600V fuses included
  • Meets NEC 2011
  • Size: 18.5"L x 14"W x 4.6"D
  • Box Size: 24"L x 19"W x 6"D
  • Weight: 16 Lbs
  • MN Part Number: MNPV8HV Disco 3R PV Disconnecting Combiner
  • Product Detail:

    Availability
    1 In Stock.  Need Larger Quantities? Give Us a Call!


    Qty.Sale Price
    1 +$594.00


    Part Num. Quantity  
    COLO-00975

    Additional Information:



    A new section in Article 690 of the NEC codes will be introduced to increase the electrical and fire safety of photovoltaic (PV) systems on buildings—in particular, for the emergency responders working on or near the power lines that may potentially contain live PV circuits. For PV systems installed on roofs of buildings, PV source circuits will be required to de-energized within 10 seconds of when emergency shutdown is initiated or when the PV power source disconnecting means is opened. Local municipalities are already starting to require the use of the Emergency Shutdown system. (City of Anaheim Fire Dept Specs & Req) MidNite Solar has all the needed equipment to install the Emergency Shutdown systems, including the battery disconnect modules to allow for disabling anything battery based including the Inverter and AC generator. Actual html for cut and paste: A new section in Article 690 of the NEC codes will be introduced to increase the electrical and fire safety of photovoltaic (PV) systems on buildings—in particular, for the emergency responders working on or near the power lines that may potentially contain live PV circuits. For PV systems installed on roofs of buildings, PV source circuits will be required to de-energized within 10 seconds of when emergency shutdown is initiated or when the PV power source disconnecting means is opened.

    Local municipalities are already starting to require the use of the Emergency Shutdown system. (City of Anaheim Fire Dept Specs & Req) MidNite Solar has all the needed equipment to install the Emergency Shutdown systems, including the battery disconnect modules to allow for disabling anything battery based including the Inverter and AC generator.

    PDFs:

       MNPV8HV-Disco Nema 3R Combiner Spec Sheet
       MidNite Disco Combiners Brochure
       MidNite Disco Combiner User Manual