Locally owned and operated in Colorado since 2002--Everything You Need to Go Solar!
{"id":1868417695833,"title":"Midnite Solar Circuit Breaker 20 amp Din Rail Mount 120\/240 VAC 2 Pole - MNEAC20-2P","handle":"mneac20-2p-breaker","description":"\u003cdiv class=\"ui-tabs-panel ui-corner-bottom ui-widget-content\" id=\"tabs-1\" role=\"tabpanel\" aria-hidden=\"false\" aria-labelledby=\"ui-id-1\"\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003e20 amp din rail mount 120\/240 VAC branch circuit rated 489 two-pole breaker. 10,000 AIC. MidNite's breakers are rated to break the full rated load at the rated voltage repeatedly, with NO DAMAGE. Always use a properly sized breaker for disconnecting. All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure. Breaker torque value: 20 In-Lbs (2.3NM). Type 1 indoor rating. Listed for US and Canada.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20A Two-Pole Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e20 amp overcurrent protection for 120\/240 VAC branch circuits, switching both legs simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e100% Continuous Duty Rated:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCan be used at 100% of rated current when mounted in a MidNite enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDin Rail Mount:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eStandard 26mm (1 inch) wide for tool-free installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10,000 AIC:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh interrupt capacity for robust fault protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBranch Circuit Rated 489A:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompliant with branch circuit requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eListed for US \u0026amp; Canada:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCertified for use in both countries.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eManufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMidNite Solar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMNEAC20-2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAmperage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e20A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e120\/240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePoles\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTwo-pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWidth\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e26mm (1 inch)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAIC Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e10,000 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBranch Circuit Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e489A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTorque Value\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e20 In-Lbs (2.3NM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEnvironmental Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eType 1 (Indoor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCertifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eListed for US \u0026amp; Canada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ui-tabs-panel ui-corner-bottom ui-widget-content\" id=\"tabs-4\" role=\"tabpanel\" aria-hidden=\"true\" aria-labelledby=\"ui-id-2\" style=\"display: none;\"\u003e\n\u003cdiv class=\"grp-of-series\"\u003e\n\u003cdiv class=\"block\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2018-11-22T11:25:46-07:00","created_at":"2018-11-22T11:25:47-07:00","vendor":"Midnite Solar","type":"Breakers \u0026 Fuses","tags":["AC Breakers","All products","Electrical Parts","feed-sl-9","Type_Breakers \u0026 Fuses","Type_Breakers and Fuses"],"price":4000,"price_min":4000,"price_max":4000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":18342650970201,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MNEAC20-2P","requires_shipping":true,"taxable":false,"featured_image":null,"available":true,"name":"Midnite Solar Circuit Breaker 20 amp Din Rail Mount 120\/240 VAC 2 Pole - MNEAC20-2P","public_title":null,"options":["Default Title"],"price":4000,"weight":454,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/www.solarpanelstore.com\/cdn\/shop\/products\/MNEAC20_50-2P_Lg_27f6bb3c-ec73-4f16-8c77-98ebb056252c.jpg?v=1542913050"],"featured_image":"\/\/www.solarpanelstore.com\/cdn\/shop\/products\/MNEAC20_50-2P_Lg_27f6bb3c-ec73-4f16-8c77-98ebb056252c.jpg?v=1542913050","options":["Title"],"media":[{"alt":null,"id":514793013388,"position":1,"preview_image":{"aspect_ratio":1.172,"height":256,"width":300,"src":"\/\/www.solarpanelstore.com\/cdn\/shop\/products\/MNEAC20_50-2P_Lg_27f6bb3c-ec73-4f16-8c77-98ebb056252c.jpg?v=1542913050"},"aspect_ratio":1.172,"height":256,"media_type":"image","src":"\/\/www.solarpanelstore.com\/cdn\/shop\/products\/MNEAC20_50-2P_Lg_27f6bb3c-ec73-4f16-8c77-98ebb056252c.jpg?v=1542913050","width":300}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv class=\"ui-tabs-panel ui-corner-bottom ui-widget-content\" id=\"tabs-1\" role=\"tabpanel\" aria-hidden=\"false\" aria-labelledby=\"ui-id-1\"\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003e20 amp din rail mount 120\/240 VAC branch circuit rated 489 two-pole breaker. 10,000 AIC. MidNite's breakers are rated to break the full rated load at the rated voltage repeatedly, with NO DAMAGE. Always use a properly sized breaker for disconnecting. All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure. Breaker torque value: 20 In-Lbs (2.3NM). Type 1 indoor rating. Listed for US and Canada.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20A Two-Pole Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e20 amp overcurrent protection for 120\/240 VAC branch circuits, switching both legs simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e100% Continuous Duty Rated:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCan be used at 100% of rated current when mounted in a MidNite enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDin Rail Mount:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eStandard 26mm (1 inch) wide for tool-free installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10,000 AIC:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh interrupt capacity for robust fault protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBranch Circuit Rated 489A:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompliant with branch circuit requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eListed for US \u0026amp; Canada:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCertified for use in both countries.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eManufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMidNite Solar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMNEAC20-2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAmperage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e20A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e120\/240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePoles\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTwo-pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWidth\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e26mm (1 inch)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAIC Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e10,000 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBranch Circuit Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e489A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTorque Value\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e20 In-Lbs (2.3NM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEnvironmental Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eType 1 (Indoor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCertifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eListed for US \u0026amp; Canada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ui-tabs-panel ui-corner-bottom ui-widget-content\" id=\"tabs-4\" role=\"tabpanel\" aria-hidden=\"true\" aria-labelledby=\"ui-id-2\" style=\"display: none;\"\u003e\n\u003cdiv class=\"grp-of-series\"\u003e\n\u003cdiv class=\"block\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

Midnite Solar Circuit Breaker 20 amp Din Rail Mount 120/240 VAC 2 Pole - MNEAC20-2P

Product Description
$40.00
Maximum quantity available reached.

20 amp din rail mount 120/240 VAC branch circuit rated 489 two-pole breaker. 10,000 AIC. MidNite's breakers are rated to break the full rated load at the rated voltage repeatedly, with NO DAMAGE. Always use a properly sized breaker for disconnecting. All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure. Breaker torque value: 20 In-Lbs (2.3NM). Type 1 indoor rating. Listed for US and Canada.


Key Features & Benefits

20A Two-Pole Rating: 20 amp overcurrent protection for 120/240 VAC branch circuits, switching both legs simultaneously.

100% Continuous Duty Rated: Can be used at 100% of rated current when mounted in a MidNite enclosure.

Din Rail Mount: Standard 26mm (1 inch) wide for tool-free installation.

10,000 AIC: High interrupt capacity for robust fault protection.

Branch Circuit Rated 489A: Compliant with branch circuit requirements.

Listed for US & Canada: Certified for use in both countries.


Technical Specifications

Specification Detail
Manufacturer MidNite Solar
Model MNEAC20-2P
Amperage 20A
Voltage 120/240 VAC
Poles Two-pole
Width 26mm (1 inch)
AIC Rating 10,000 A
Branch Circuit Rating 489A
Torque Value 20 In-Lbs (2.3NM)
Environmental Rating Type 1 (Indoor)
Certifications Listed for US & Canada