{"id":8075652923631,"title":"SolarEdge P960 Power Optimizer 960W 60V - P960","handle":"solaredge-p960-power-optimizer-960w-60v-p960","description":"\u003cp data-mce-fragment=\"1\"\u003eAll SolarEdge power optimizers can be used with crystalline silicon PV modules to provide module-level MPPT and performance monitoring, and are designed to work exclusively with SolarEdge inverters. All power optimizers have 99.5% peak efficiency and are backward compatible with older SolarEdge products.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe P730, P801, P850, P1100, and P1101 dual-module optimizers (two modules are connected in series, then connected to the optimizer), and the P860 and P960 dual-module optimizers (two modules in parallel connected to the optimizer) are compatible only with the SolarEdge three-phase inverters. See Datasheets for RSD compliance. \u003cbr\u003e\u003cbr\u003eSolarEdge optimizers can be attached to most PV mounting systems using a single fastener; grounding can be accomplished via the included star washer, UL 2703 listed racking with integrated grounding, or through a ground lug, depending on racking. \u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e- Increased energy harvest through module-level optimizers, with 99.5% efficiency\u003cbr\u003e- Mitigates losses due to module mismatch and partial shading\u003cbr\u003e- Module-level shutdown (1 VDC per module) inherently compliant with NEC 2014 and - NEC 2017 690.12 requirements (residential models, see Datasheets for commercial models)\u003cbr\u003e- NEMA 6P, IP68 environmental protection rating\u003cbr\u003e- Operating temperatures of -40 °F to +185 °F (-40 °C to +85 °C)\u003cbr\u003e- Available for 60-cell PV modules up to 370 W and 72-cell modules up to 400 W\u003cbr\u003e- 99.5% DC optimizer efficiency\u003cbr\u003e- 25-year warranty\u003cbr\u003e- Compliant with: IEC62109-1 (class II safety) and UL1741\u003cbr\u003e- Compliant to Rule 21 (UL 1741-SA) requirements, when installed with a SolarEdge inverters. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/6003\/5417\/files\/2159_565-0235_Spec_Sheet_960P_860P.pdf?v=1687538137\"\u003eSolarEdge P960 Power Optimizer 960W 60V - P960 Spec Sheet\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv aria-labelledby=\"ui-id-1\" aria-hidden=\"false\" role=\"tabpanel\" id=\"tabs-1\" class=\"ui-tabs-panel ui-corner-bottom ui-widget-content\"\u003e\u003c\/div\u003e","published_at":"2023-06-23T10:29:37-06:00","created_at":"2023-06-23T10:29:37-06:00","vendor":"SolarEdge","type":"Microinverter\/Optimizer","tags":["All products","Brand_SolarEdge","feed-sl-15","Solar Power Optimizers","SolarEdge Inverters and Optimizers","SolarEdge Products","Type_Grid-Tie Microinverters\/Optimizers"],"price":11600,"price_min":11600,"price_max":11600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":43987412746479,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"P960","requires_shipping":true,"taxable":false,"featured_image":null,"available":true,"name":"SolarEdge P960 Power Optimizer 960W 60V - P960","public_title":null,"options":["Default Title"],"price":11600,"weight":907,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.solarpanelstore.com\/cdn\/shop\/files\/SOLAREDGEP960960WOPTIMIZER.png?v=1687538188"],"featured_image":"\/\/www.solarpanelstore.com\/cdn\/shop\/files\/SOLAREDGEP960960WOPTIMIZER.png?v=1687538188","options":["Title"],"media":[{"alt":"SolarEdge P960 Power Optimizer 960W 60V - P960","id":32443048001775,"position":1,"preview_image":{"aspect_ratio":0.705,"height":1162,"width":819,"src":"\/\/www.solarpanelstore.com\/cdn\/shop\/files\/SOLAREDGEP960960WOPTIMIZER.png?v=1687538188"},"aspect_ratio":0.705,"height":1162,"media_type":"image","src":"\/\/www.solarpanelstore.com\/cdn\/shop\/files\/SOLAREDGEP960960WOPTIMIZER.png?v=1687538188","width":819}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp data-mce-fragment=\"1\"\u003eAll SolarEdge power optimizers can be used with crystalline silicon PV modules to provide module-level MPPT and performance monitoring, and are designed to work exclusively with SolarEdge inverters. All power optimizers have 99.5% peak efficiency and are backward compatible with older SolarEdge products.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe P730, P801, P850, P1100, and P1101 dual-module optimizers (two modules are connected in series, then connected to the optimizer), and the P860 and P960 dual-module optimizers (two modules in parallel connected to the optimizer) are compatible only with the SolarEdge three-phase inverters. See Datasheets for RSD compliance. \u003cbr\u003e\u003cbr\u003eSolarEdge optimizers can be attached to most PV mounting systems using a single fastener; grounding can be accomplished via the included star washer, UL 2703 listed racking with integrated grounding, or through a ground lug, depending on racking. \u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e- Increased energy harvest through module-level optimizers, with 99.5% efficiency\u003cbr\u003e- Mitigates losses due to module mismatch and partial shading\u003cbr\u003e- Module-level shutdown (1 VDC per module) inherently compliant with NEC 2014 and - NEC 2017 690.12 requirements (residential models, see Datasheets for commercial models)\u003cbr\u003e- NEMA 6P, IP68 environmental protection rating\u003cbr\u003e- Operating temperatures of -40 °F to +185 °F (-40 °C to +85 °C)\u003cbr\u003e- Available for 60-cell PV modules up to 370 W and 72-cell modules up to 400 W\u003cbr\u003e- 99.5% DC optimizer efficiency\u003cbr\u003e- 25-year warranty\u003cbr\u003e- Compliant with: IEC62109-1 (class II safety) and UL1741\u003cbr\u003e- Compliant to Rule 21 (UL 1741-SA) requirements, when installed with a SolarEdge inverters. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0079\/6003\/5417\/files\/2159_565-0235_Spec_Sheet_960P_860P.pdf?v=1687538137\"\u003eSolarEdge P960 Power Optimizer 960W 60V - P960 Spec Sheet\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv aria-labelledby=\"ui-id-1\" aria-hidden=\"false\" role=\"tabpanel\" id=\"tabs-1\" class=\"ui-tabs-panel ui-corner-bottom ui-widget-content\"\u003e\u003c\/div\u003e"}

SolarEdge P960 Power Optimizer 960W 60V - P960

Product Description
$116.00
Maximum quantity available reached.

All SolarEdge power optimizers can be used with crystalline silicon PV modules to provide module-level MPPT and performance monitoring, and are designed to work exclusively with SolarEdge inverters. All power optimizers have 99.5% peak efficiency and are backward compatible with older SolarEdge products.

The P730, P801, P850, P1100, and P1101 dual-module optimizers (two modules are connected in series, then connected to the optimizer), and the P860 and P960 dual-module optimizers (two modules in parallel connected to the optimizer) are compatible only with the SolarEdge three-phase inverters. See Datasheets for RSD compliance.

SolarEdge optimizers can be attached to most PV mounting systems using a single fastener; grounding can be accomplished via the included star washer, UL 2703 listed racking with integrated grounding, or through a ground lug, depending on racking. 

Features:
- Increased energy harvest through module-level optimizers, with 99.5% efficiency
- Mitigates losses due to module mismatch and partial shading
- Module-level shutdown (1 VDC per module) inherently compliant with NEC 2014 and - NEC 2017 690.12 requirements (residential models, see Datasheets for commercial models)
- NEMA 6P, IP68 environmental protection rating
- Operating temperatures of -40 °F to +185 °F (-40 °C to +85 °C)
- Available for 60-cell PV modules up to 370 W and 72-cell modules up to 400 W
- 99.5% DC optimizer efficiency
- 25-year warranty
- Compliant with: IEC62109-1 (class II safety) and UL1741
- Compliant to Rule 21 (UL 1741-SA) requirements, when installed with a SolarEdge inverters. 